Skip to content

Latest commit

 

History

History
150 lines (112 loc) · 8.95 KB

File metadata and controls

150 lines (112 loc) · 8.95 KB

IPMI records

CommonHeader

Platform Management FRU Information Storage Definition, Table 8-1

Name Type Opt
internal_use_offs int (u8)
chassis_info_offs int (u8)
board_info_offs int (u8)
product_info_offs int (u8)
multirecord_offs int (u8)

ChassisInfo

Platform Management FRU Information Storage Definition, Table 10-1

Name Type Opt
type int (u8)
part_number str
serial_number str
custom_info_fields strarray

BoardInfo

Platform Management FRU Information Storage Definition, Table 11-1

Name Type Opt
language_code int (u8)
mfg_date_time int (u24)
manufacturer str
product_name str
serial_number str
part_number str
fru_file_id str
custom_info_fields strarray

ProductInfo

Platform Management FRU Information Storage Definition, Table 12-1

Name Type Opt
language_code int (u8)
manufacturer str
product_name str
part_number str
version str
serial_number str
asset_tag str
fru_file_id str
custom_info_fields strarray

InternalUse

Platform Management FRU Information Storage Definition, Table 9-1

Name Type Opt
data bytes

PowerSupplyInformation

Platform Management FRU Information Storage Definition, Table 18-1

Name Type Opt
predictive_fail_lower_thresh int (u8)
combined_wattage int (u16) no_combined_voltages
voltage1 int (u4) 12v, -12v, 5v, 3.3v
voltage2 int (u4) 12v, -12v, 5v, 3.3v
holdup_time int (u4)
peak_capacity int (u12) unspecified
pin_polarity int (u1)
hot_swap int (u1)
autoswitch int (u1)
pfc int (u1)
predictive_fail_support int (u1)
dropout_tolerance int (u8)
high_freq int (u8) only_dc
low_freq int (u8) accepts_dc
high_input_voltage_2 int (s16)
low_input_voltage_2 int (s16)
high_input_voltage_1 int (s16)
low_input_voltage_1 int (s16)
inrush_interval int (u8)
inrush_current int (u8) unspecified
peak_va int (u16) unspecified
overall_capacity int (u12)

DCOutput

Platform Management FRU Information Storage Definition, Table 18-2

Name Type Opt
standby_enable int (u1)
output_number int (u4) P1_VADJ, P1_3P3V, P1_12P0V, P1_VIO_B_M2C, P1_VREF_A_M2C, P1_VREF_B_M2C, P2_VADJ, P2_3P3V, P2_12P0V, P2_VIO_B_M2C, P2_VREF_A_M2C, P2_VREF_B_M2C
nominal_voltage int (u16)
max_neg_voltage int (u16)
max_pos_voltage int (u16)
max_noise_pk2pk int (u16)
min_current_draw int (u16)
max_current_draw int (u16)

DCLoad

Platform Management FRU Information Storage Definition, Table 18-4

Name Type Opt
output_number int (u4) P1_VADJ, P1_3P3V, P1_12P0V, P1_VIO_B_M2C, P1_VREF_A_M2C, P1_VREF_B_M2C, P2_VADJ, P2_3P3V, P2_12P0V, P2_VIO_B_M2C, P2_VREF_A_M2C, P2_VREF_B_M2C
nominal_voltage int (u16)
min_voltage int (u16)
max_voltage int (u16)
max_noise_pk2pk int (u16)
min_current_load int (u16)
max_current_load int (u16)

MgmtAccessRecord

Platform Management FRU Information Storage Definition, Table 18-6

Name Type Opt
id int (u8) sys_mgmt_url, sys_name, sys_ping_addr, comp_mgmt_url, comp_name, comp_ping_addr, sys_unique_id
blob bytes