Skip to content

Verification case ventilation_4 is out of tolerance #2240

@mcgratta

Description

@mcgratta

The verification case called ventilation_4 is out of tolerance. When I investigated, I noticed that the expected solution and the analytical solution are the same, and the out of tolerance warning is related to a difference in the ranges over which the comparison is made. Was this case ever working? I ask because there are other verification cases that are out of tolerance that were never flagged by cfastbot. Given that this case considers a complicated doorway flow profile, I wonder how an analytical solution can be derived outside of running CFAST.

Metadata

Metadata

Assignees

Labels

No labels
No labels

Type

No type

Projects

No projects

Milestone

No milestone

Relationships

None yet

Development

No branches or pull requests

Issue actions