DRAFT: New product names for websites#1192
DRAFT: New product names for websites#1192tech3371 wants to merge 2 commits intoIMAP-Science-Operations-Center:devfrom
Conversation
There was a problem hiding this comment.
I reviewed this file for all data levels.
There was a problem hiding this comment.
reviewed this file
There was a problem hiding this comment.
reviewed this file
| @@ -0,0 +1,11 @@ | |||
| swe, l0, sci, | |||
There was a problem hiding this comment.
| swe, l0, sci, | |
| swe, l0, sci |
| swe, ancillary, config | ||
| swe, ancillary, esa-lut | ||
| swe, ancillary, eu-conversion | ||
| swe, ancillary, l1b-in-flight-cal |
There was a problem hiding this comment.
verified that these are accurate.
| lo,l1b, prostar | ||
| lo,l1b,nhk | ||
| lo,l1b,shk | ||
| lo,L1b,good-times |
There was a problem hiding this comment.
I think L1b good-times and L1b bgrates going to move to L1c to be consistent with Hi and Ultra.
| hi, l1b, 45sensor-de | ||
| hi, l1b, 90sensor-de | ||
| hi, l1b, hk | ||
| hi, l1c, 45sensor-pset |
There was a problem hiding this comment.
I think there are new products that need to be added here - maybe L1b Background Subtraction and L1c Goodtimes plus L2 Validated Goodtimes??
There was a problem hiding this comment.
My comment above adds the new hi l1b goodtimes products. There are not backgrounds products, just the addition of the background subtraction algorithm to L1C PSET code.
| codice, l1a, hi-sectored | ||
| codice, l1a, lo-counters-aggregated | ||
| codice, l1a, lo-counters-singles | ||
| codice, l1a, lo-nsw-angular |
There was a problem hiding this comment.
I believe the CoDICE team has said that the angular products are going away...
| codice, l3a, hi-direct-events | ||
| codice, l3a, lo-direct-events | ||
| codice, l3a, lo-heplus-3d-distribution | ||
| codice, l3a, lo-heplus2-3d-distribution |
There was a problem hiding this comment.
@jtniehof suggested changing this product to lo-heplusplus-3d-distribution in order to match the term used in the l2-lo-efficiency ancillary file and a variable name in lo-partial-densities. We haven't actually changed it yet.
There was a problem hiding this comment.
I see. It's ok to keep what we have if it's not changed yet. No rush. Web team don't mind making smaller updates in the future.
There was a problem hiding this comment.
Right now because of the name mismatch, we aren't making any lo-heplus2-3d-distribution, and we'll probably change the product name rather than work around the mismatch. So I'd be good with just going ahead and putting the new heplusplus into the system instead of heplus2.
| mag, l1d, norm-srf | ||
| mag, l2, burst-srf | ||
| mag, l2, norm-srf |
There was a problem hiding this comment.
L2 and L1D have other reference frames as well. The complete list:
burst-dsrf
burst-gse
burst-rtn
burst-srf
norm-dsrf
norm-gse
norm-rtn
norm-srf
There was a problem hiding this comment.
Those produces cdf with those descriptor now?
| glows, l1b, de | ||
| glows, l1b, hist | ||
| glows, l2, hist | ||
| glows, l3a, hist |
There was a problem hiding this comment.
There are more L3 descriptors, but I will leave that for Menlo to define more thoroughly. L0-L2 are correct
There was a problem hiding this comment.
Additional products created by alternate triggering mechanism:
glows, l3b, ion-rate-profile
glows, l3c, sw-profile
glows, l3d, solar-hist
glows, l3e, survival-probability-lo
glows, l3e, survival-probability-hi-90
glows, l3e, survival-probability-hi-45
glows, l3e, survival-probability-ul-sf
glows, l3e, survival-probability-ul-hf
| glows, ancillary, calibration-data | ||
| glows, ancillary, conversion-table-for-anc-data | ||
| glows, ancillary, exclusions-by-instr-team | ||
| glows, ancillary, map-of-excluded-regions | ||
| glows, ancillary, map-of-extra-helio-bckgrd | ||
| glows, ancillary, map-of-uv-sources | ||
| glows, ancillary, pipeline-settings | ||
| glows, ancillary, suspected-transients | ||
| glows, ancillary, time-dep-bckgrd |
There was a problem hiding this comment.
There are several more GLOWS ones that are hidden from the dependency system, in the L3b-L3e code:
glows, ancillary, bad-days-list
glows, ancillary, electron-density-2010a
glows, ancillary, energy-grid-hi
glows, ancillary, energy-grid-lo
glows, ancillary, energy-grid-ultra
glows, ancillary, ionization-files
glows, ancillary, lya-2010a
glows, ancillary, photoion-2010a
glows, ancillary, pipeline-settings-l3bcde
glows, ancillary, plasma-speed-2010a
glows, ancillary, proton-density-2010a
glows, ancillary, tess-xyz-8
glows, ancillary, uv-anisotropy-1CR
glows, ancillary, uv-anisotropy-2010a
glows, ancillary, WawHelioIonMP
|
Thanks for looking to update this...it'll hopefully save me some "custom" typing when checking on jobs :) |
| hi, l3, h90-spx-h-hf-sp-ram-hae-4deg-1yr | ||
| hi, l3, h90-spx-h-hf-sp-ram-hae-6deg-1yr | ||
| hi, l3, hic-spx-h-hf-sp-full-hae-4deg-1yr | ||
| hi, l3, hic-spx-h-hf-sp-full-hae-6deg-1yr |
There was a problem hiding this comment.
Additional products created by alternate triggering:
hi, l3, hic-ena-h-hf-nsp-full-hae-6deg-1yr
hi, l3, hic-ena-h-hf-sp-full-hae-6deg-1yr
hi, l3, hic-ena-h-hf-nsp-full-hae-4deg-1yr
hi, l3, hic-ena-h-hf-sp-full-hae-4deg-1yr
hi, l3, h45-ena-h-sf-sp-ram-hae-4deg-1yr
hi, l3, h45-ena-h-sf-sp-anti-hae-4deg-1yr
hi, l3, h90-ena-h-sf-sp-ram-hae-4deg-1yr
hi, l3, h90-ena-h-sf-sp-anti-hae-4deg-1yr
hi, l3, h90-ena-h-sf-sp-full-hae-4deg-6mo
hi, l3, h45-ena-h-sf-sp-ram-hae-6deg-1yr
hi, l3, h45-ena-h-sf-sp-anti-hae-6deg-1yr
hi, l3, h90-ena-h-sf-sp-ram-hae-6deg-1yr
hi, l3, h90-ena-h-sf-sp-anti-hae-6deg-1yr
hi, l3, h90-ena-h-sf-sp-full-hae-6deg-6mo
hi, l3, h45-ena-h-hf-sp-ram-hae-4deg-1yr
hi, l3, h45-ena-h-hf-sp-anti-hae-4deg-1yr
hi, l3, h90-ena-h-hf-sp-ram-hae-4deg-1yr
hi, l3, h90-ena-h-hf-sp-anti-hae-4deg-1yr
hi, l3, h45-ena-h-hf-sp-full-hae-4deg-6mo
hi, l3, h90-ena-h-hf-sp-full-hae-4deg-6mo
hi, l3, h45-ena-h-hf-sp-ram-hae-6deg-1yr
hi, l3, h45-ena-h-hf-sp-anti-hae-6deg-1yr
hi, l3, h90-ena-h-hf-sp-ram-hae-6deg-1yr
hi, l3, h90-ena-h-hf-sp-anti-hae-6deg-1yr
hi, l3, h45-ena-h-hf-sp-full-hae-6deg-6mo
hi, l3, h90-ena-h-hf-sp-full-hae-6deg-6mo
| lo,l3,l090-spx-h-sf-nsp-ram-hae-6deg-1yr | ||
| lo,l3,l090-spx-h-sf-sp-ram-hae-6deg-1yr | ||
| lo,l3,l090-spxnbs-h-hk-nsp-ram-hae-6deg-1yr | ||
| lo,l3,l090-spxnbs-h-sf-nsp-ram-hae-6deg-1yr No newline at end of file |
There was a problem hiding this comment.
Additional products:
lo, l3, l090-ena-h-sf-sp-ram-hae-6deg-1yr
lo, l3, l090-ena-h-hf-sp-ram-hae-6deg-1yr
| ultra, l3, ulc-spx-h-hf-sp-full-hae-4deg-6mo | ||
| ultra, l3, ulc-spx-h-hf-sp-full-hae-6deg-1yr | ||
| ultra, l3, ulc-spx-h-hf-sp-full-hae-6deg-3mo | ||
| ultra, l3, ulc-spx-h-hf-sp-full-hae-6deg-6mo |
There was a problem hiding this comment.
Additional descriptors:
ultra, l3, u45-ena-h-hf-sp-full-hae-2deg-3mo
ultra, l3, u45-ena-h-sf-sp-full-hae-2deg-3mo
ultra, l3, u45-ena-h-hf-sp-full-hae-4deg-3mo
ultra, l3, u45-ena-h-sf-sp-full-hae-4deg-3mo
ultra, l3, u45-ena-h-hf-sp-full-hae-6deg-3mo
ultra, l3, u45-ena-h-sf-sp-full-hae-6deg-3mo
ultra, l3, u45-ena-h-hf-sp-full-hae-2deg-6mo
ultra, l3, u45-ena-h-sf-sp-full-hae-2deg-6mo
ultra, l3, u45-ena-h-hf-sp-full-hae-4deg-6mo
ultra, l3, u45-ena-h-sf-sp-full-hae-4deg-6mo
ultra, l3, u45-ena-h-hf-sp-full-hae-6deg-6mo
ultra, l3, u45-ena-h-sf-sp-full-hae-6deg-6mo
ultra, l3, u45-ena-h-hf-sp-full-hae-2deg-1yr
ultra, l3, u45-ena-h-sf-sp-full-hae-2deg-1yr
ultra, l3, u45-ena-h-hf-sp-full-hae-4deg-1yr
ultra, l3, u45-ena-h-sf-sp-full-hae-4deg-1yr
ultra, l3, u45-ena-h-hf-sp-full-hae-6deg-1yr
ultra, l3, u45-ena-h-sf-sp-full-hae-6deg-1yr
ultra, l3, u90-ena-h-hf-sp-full-hae-2deg-3mo
ultra, l3, u90-ena-h-sf-sp-full-hae-2deg-3mo
ultra, l3, u90-ena-h-hf-sp-full-hae-4deg-3mo
ultra, l3, u90-ena-h-sf-sp-full-hae-4deg-3mo
ultra, l3, u90-ena-h-hf-sp-full-hae-6deg-3mo
ultra, l3, u90-ena-h-sf-sp-full-hae-6deg-3mo
ultra, l3, u90-ena-h-hf-sp-full-hae-2deg-6mo
ultra, l3, u90-ena-h-sf-sp-full-hae-2deg-6mo
ultra, l3, u90-ena-h-hf-sp-full-hae-4deg-6mo
ultra, l3, u90-ena-h-sf-sp-full-hae-4deg-6mo
ultra, l3, u90-ena-h-hf-sp-full-hae-6deg-6mo
ultra, l3, u90-ena-h-sf-sp-full-hae-6deg-6mo
ultra, l3, u90-ena-h-hf-sp-full-hae-2deg-1yr
ultra, l3, u90-ena-h-sf-sp-full-hae-2deg-1yr
ultra, l3, u90-ena-h-hf-sp-full-hae-4deg-1yr
ultra, l3, u90-ena-h-sf-sp-full-hae-4deg-1yr
ultra, l3, u90-ena-h-hf-sp-full-hae-6deg-1yr
ultra, l3, u90-ena-h-sf-sp-full-hae-6deg-1yr
ultra, l3, ulc-ena-h-hf-nsp-full-hae-2deg-3mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-4deg-3mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-6deg-3mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-2deg-6mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-4deg-6mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-6deg-6mo
ultra, l3, ulc-ena-h-hf-nsp-full-hae-2deg-1yr
ultra, l3, ulc-ena-h-hf-nsp-full-hae-4deg-1yr
ultra, l3, ulc-ena-h-hf-nsp-full-hae-6deg-1yr
ultra, l3, ulc-ena-h-hf-sp-full-hae-2deg-3mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-4deg-3mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-6deg-3mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-2deg-6mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-4deg-6mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-6deg-6mo
ultra, l3, ulc-ena-h-hf-sp-full-hae-2deg-1yr
ultra, l3, ulc-ena-h-hf-sp-full-hae-4deg-1yr
ultra, l3, ulc-ena-h-hf-sp-full-hae-6deg-1yr
| hi, l1b, 45sensor-de | ||
| hi, l1b, 90sensor-de | ||
| hi, l1b, hk |
There was a problem hiding this comment.
| hi, l1b, 45sensor-de | |
| hi, l1b, 90sensor-de | |
| hi, l1b, hk | |
| hi, l1a, 45sensor-de | |
| hi, l1a, 90sensor-de | |
| hi, l1a, 45sensor-diagfee | |
| hi, l1a, 90sensor-diagfee | |
| hi, l1a, 45sensor-hist | |
| hi, l1a, 90sensor-hist | |
| hi, l1a, 45sensor-hk | |
| hi, l1a, 90sensor-hk | |
| hi, l1a, 45sensor-memdmp | |
| hi, l1a, 90sensor-memdmp | |
| hi, l1b, 45sensor-hk | |
| hi, l1b, 90sensor-hk | |
| hi, l1b, 45sensor-de | |
| hi, l1b, 90sensor-de | |
| hi, l1b, 45sensor-goodtimes | |
| hi, l1b, 90sensor-goodtimes |
| @@ -0,0 +1,4 @@ | |||
| idex, l0, raw | |||
There was a problem hiding this comment.
This looks great! We will also have idex,l1a,msg and idex,l1b,msg soon. They are housekeeping but will be nice to have on the website dropdown
There was a problem hiding this comment.
I think this is also missing idex,l1a,sci-1week
| @@ -0,0 +1,4 @@ | |||
| idex, l0, raw | |||
There was a problem hiding this comment.
I think this is also missing idex,l1a,sci-1week
| ultra, l1a, 90sensor-params | ||
| ultra, l1a, 90sensor-rates | ||
|
|
||
| ultra, l1b, 45sensor-de |
There was a problem hiding this comment.
ultra, l1b, 90sensor-goodtimes
ultra, l1b 45sensor-goodtimes
|
What is the timeline for being able to merge this in? Current availabilty of the L3 products on the website:
This is really bad for CoDICE and pretty bad for SWAPI. Maps are less important at the moment, but:
|
@jtniehof I thought I could get this done in a day or less but I haven't been able to go back to it. I can prioritize this. I know our web team is waiting for this too. |
Change Summary
Overview
File changes
This PR is just for collaboration of gathering correct descriptor names needed for website updates.
These products name for each level will be used to filter science CDF files on the IMAP SDC website. Appreciate review of if these descriptor names are accurate or not!!
Testing