27 changes: 25 additions & 2 deletions app/routers/compute/models.py
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
from enum import IntEnum
from typing import Annotated

from pydantic import ConfigDict, Field, StrictBool, field_serializer
from pydantic import ConfigDict, Field, StrictBool, field_serializer, field_validator

from ...types.base import IRIBaseModel

Expand All @@ -17,7 +17,30 @@ class ResourceSpec(IRIBaseModel):
cpu_cores_per_process: Annotated[int | None, Field(ge=1, description="Number of CPU cores to allocate per process")] = None
gpu_cores_per_process: Annotated[int | None, Field(ge=1, description="Number of GPU cores to allocate per process")] = None
exclusive_node_use: Annotated[StrictBool, Field(description="Whether to request exclusive use of allocated nodes")] = True
memory: Annotated[int | None, Field(ge=1, description="Amount of memory to allocate in bytes")] = None
memory: Annotated[str | None, Field(min_length=4, pattern=r"^[1-9]\d*(MiB|GiB)$", examples=["1GiB", "512MiB", "64GiB"], description="Amount of memory to allocate in IEC binary format (e.g. '512MiB', '4GiB')")] = None
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Some thoughts:

  • should we also add larger memory units (Tib, etc) for "future-proofing"?
  • should we use an object here to explicitly represent things: { value=100, unit="Gib" } (where unit is an enum)?
  • what usecase does this code help? Sure, people can now send 256Gib but if you need to work with these values, you'll need encode/decode type code when sending/receiving the values. Not a strong opinion, but it's worth thinking about.


@field_validator("memory")
@classmethod
def validate_memory(cls, v):
"""Validate memory string in IEC binary format (e.g. '512MiB', '4GiB') and convert to bytes."""
if v is None:
return v

v = v.strip()
units = {"mib": 2**20, "gib": 2**30}

lower = v.lower()
for unit, multiplier in units.items():
if lower.endswith(unit):
number_part = lower[: -len(unit)].strip()
try:
value = int(number_part)
except ValueError as ex:
raise ValueError("Memory value must be an integer followed by MiB or GiB") from ex
if value < 1:
raise ValueError("Memory value must be a positive integer")
return value * multiplier
raise ValueError("Memory must use units MiB or GiB (e.g. '512MiB', '4GiB')")


class JobAttributes(IRIBaseModel):