Skip to content

Compatibility with Siemens/Cinterion TC35i#7

Open
albertjan wants to merge 4 commits intorapidsms:masterfrom
albertjan:master
Open

Compatibility with Siemens/Cinterion TC35i#7
albertjan wants to merge 4 commits intorapidsms:masterfrom
albertjan:master

Conversation

@albertjan
Copy link
Copy Markdown

Added a check for a model at boot time. If that is TC35i it changes the +CNMI command and skips the +WIND command.

Also made a change in the pdusmshandler This now resends the sms when a CMS 500 error is received. This is because the TC35i sends a 500 error on a timeout. It uses the same concept as the 515 error solution.

albertjan added 3 commits August 22, 2011 11:59
… or off. And added unit tests. The siemens TC35i needs a different CNMI command and doesn't understand the WIND command. And it will return a 500 error on a timed out sms message in stead of something more usefull.
@albertjan
Copy link
Copy Markdown
Author

Hey, is there any reason this hasn't been pulled yet? If so please tell so I can change it.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant